Company |
Product Name |
Technology Type |
Contact Information |
Red Bag Solutions
3431 Benson Ave.
Suite 100
Baltimore, MD 21227
(443) 524-4245
Fax: (443) 524-4250 |
SSM 150/75
Approved: February, 2003 |
Superheated Water |
Sanford A. Glazer Director of Compliance and Technology
ph: 443-524-4245 ext.#14
Fax: 443-524-4250
Cell:301-254-2234
E-mail: sglazer@redbag.com or
Website: www.redbag.com |
M.C.M Environmental Technologies, Inc.
One Parker Plaza
Fort Lee, NJ 07024 |
SteriMed |
Chemical Disinfection |
Karen Albretsen
Project Manager
Ph: 201- 242-1222
1-800-783-7463
Fax: 201-592-0393 |
BioSAFE Engineering LLC
485 Southpoint Circle
Building 200
Brownsburg, Indiana 46112 |
STI Chemclave
Approved: February, 2008 |
Shred/Heat/ Chemical
(sodium hydroxide) |
Brad Crain, President
Cell:765-585-4114
Richard Redpath, VP Operations
Cell:336-253-8916
Ph:317-858-8099
Fax: 317-484-4201
http://www.biosafeengineering.com/ |
Steris Corporation
5960 Heisley Rd.
Mentor, Ohio 44060 |
|
Shred/chemical sterilant (peracetic acid) |
Richard Snead
Ph:1-800-989-7575 Ext.21165
Fax:440-639-4450
www.steris.com |
Biomedical Technology Solutions, Inc.
9800 Mt. Pyramid Court, Suite 350
Englewood, CO 80112 |
Demolizer
Approved: January,2007 |
Thermal Treatment |
Don Cox, Pres.
Diane Gorden, Sr. VP of Operations
Ph: 1 866-525-2687
Fax: 303-653-0120
BMTSCORP.com |
Environmental Health Management Systems, Inc.
2613 Skyway
Grand Prairie, Texas 75052 |
Oncore MWP 2750
Approved: February, 2007 |
Shredding/ Chlorine dioxide |
Nelsen S. Slavik, PhD, President
Environmental Health Management Systems, Inc.
2613 Skyway
Grand Prairie, Texas 75052
http://www.oncoreus.com/ |
Waste & Compliance
Management, Inc.
6054 Corte Del Cedro
Carlsbad, CA 92011 |
Isolyser |
Sharps Disposal System |
Keri Tucker
Ph: 866-436-9264
Fax: 760-930-9225 www.wastewise.com or
e-mail: service@wastewise.com |
BioSAFE Engineering LLC
485 Southpoint Circle
Building 200
Brownsburg, Indiana 46112 |
WR2100 Tissue Digestor
Approved: July, 2008 |
Alkaline Hydrolysis,
Superheated water
Waste type: pathological
|
Brad Crain, President
Cell:765-585-4114
Richard Redpath, VP Operations
Cell:336-253-8916
Ph:317-858-8099
Fax: 317-484-4201
Website: http://www.biosafeengineering.com/ |
Ozonator Industries
1850 Industrial Drive
PO Box 26030
Regina, Saskatchewan
Canada S4R 897 |
Ozonator
Approved: November, 2009 |
Shredding/ Ozone
Waste type: pathological, microbiological |
Phone: 306-791-0900
Fax: 306-791-0905
www.ozonatorindustries.ca |
Positive Impact Waste Solutions, LLC
PO Box 14692
Odessa, Texas 79768 |
PIWS-3000
Approved: December 2009 |
Shred /Chemical (Calcium oxide)
Waste type: pathological, microbiological |
Timothy P. Spencer, President
Ph: 432-580-5885
Fax: 432-580-6886
www.piwsinc.com |
TrinovaMed Medical Waste Solutions, LLC
235 Jason Court
Corona, CA 91789 |
Green Machine
Approved: January, 2011 |
Shredding/ chemical (Chlorine dioxide)
Waste type: microbiological |
Brian Williams, Sr. Vice President
Ph: 909-226-0195
http://www.trinovamed.com/ |
Medline Industries, Inc.
One Medline Industries, Inc.
Mundelein, IL 60060 |
Liqui-Loc
Approved: June 2012 |
Chemical Disinfection and Solidifier
Waste type: blood and body fluids |
Phone: (800) 351-1512-8704
Website: www.medline.com |
Ecodas Corp.
1400 Hubbell Pl., Suite 1206
Seattle, WA 98101 |
Ecodas T2000 & T300
Approved: July 2012 |
Shredding and Steam Sterilization
Waste type: pathological, microbiological |
Phone: 206- 427-6641
Fax: 206-339-7259
Website: www.ecodas.com |
Disorb Systems Inc.
1800 West Indiana Ave.
Philadelphia, PA 19132 |
Super Solid Plus Approved: March 2013 |
Chemical Disinfection and Solidifier
Waste type: blood and body fluids |
Ted McLaughlin
Phone: 215-207-9010
Website: www.disorb.com |
Clean Waste Systems, LLC
3535 Plymouth Blvd. Suite 112
Plymouth, MN 55447 |
OWS-1000
Approved: May 2013 |
Shredding/ Ozone
Waste type: pathological, microbiological |
Steve Pellegrene
Phone: 763-559-9277
www.cleanwastesystems.com |
Progressive Recovery,Inc.
700 Industrial Drive
Dupo, Illinois 62239 |
Thermal Tissue Digester
Approved: November 2013 |
Alkaline hydrolysis
Waste type: pathological |
Jim Laarman, COO
Phone: (618) 286-5000
Email: jlaarman@progressive-recovery.com
www.pri-bio.com |
Viradys Medical Waste Solutions
1001 Thornblade Blvd
Greer, SC 29615 |
Viradys Medical Waste Treatment System
Approved: February 2015 |
Shred/Infrared heat |
Tony Sanchez
VP Marketing and Sales
Viradys Medical Waste Solutions
phone: 864-881-1838
tsanchez@viradys.com |
|
|
|
|
|
|